automating all operations of the incinerator

automating all operations of the incinerator Construction Constructed from heavy duty mild or aluminized steel or equal and approved equivalent Insulation Refractory material lining Combustion Temperatures Above 850 0C, controlled electronically Gas residue or retention time > 2 second at minimum 850 0C Secondary Burner Provided, Diesel fired, Fully automatic, with fuel, temperature and speedContinue reading “automating all operations of the incinerator”

TECHNICAL SPECIFICATION FOR DIESEL FIRED INCINERATOR

1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan accountingContinue reading “TECHNICAL SPECIFICATION FOR DIESEL FIRED INCINERATOR”

SPECIFICATIONS OF A DIESEL FIRED INCINERATORS

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR 1.0 INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification. 1.1 General description The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimumContinue reading “SPECIFICATIONS OF A DIESEL FIRED INCINERATORS”

Incinerator Capacity of destruction in weight: 60Kg/h

1.Capacity of destruction in weight: 60Kg/h 2.It should be able to operate not less than 10 hours/day. 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc.. 4.Design Specification: Types A, B, C, D and E of medical waste 5.“PYROLYTIC” combustion by controlling the gasification of waste.Continue reading “Incinerator Capacity of destruction in weight: 60Kg/h”

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements Primary Combustion Chamber Waste Charging Door: Provided with refractory lining with sealing gaskets Ash Removed Door: Provided with refractory lining with sealing gaskets Outer Body MOC: Mild Steel, 5mm Primary Chamber: Stainless Steel Operating Temperature :800. ± 50◦C Insulation: Insulation BrickContinue reading “Incinerator Rated Capacity: 100/KG/Hr”

TECHNICAL SPECIFICATIONS FOR NAMAPA HOSPITAL,INCINERATOR 20KG

INCINERATOR 20KG General Specifications 6mm plate steel sheel construction 11cm 1400 º C Refractory L iner Temperature controlled Burners Secondary combustion Burners Interlock Switch on Load Doors Separate Ash Door One Second secondary Residence @ 1000 º C 400 ° C Silicone Based Paint Finish. Alloy Temperature Sensor Factory wired and tested Capacity-20 kg /Continue reading “TECHNICAL SPECIFICATIONS FOR NAMAPA HOSPITAL,INCINERATOR 20KG”

multiple diesel fuel combustion chambers Incinerator

*External diameter at base 6ft 1.8m *External diameter at top 4 1/2ft 1.35m *Internal diameter at base 3ft 0.9m *Internal diameter at top 3ft 0.9m *Thickness of wall at base 18cm *Thickness of wall at top 9cm *Perpendicular height of wall 4ft *Height of Iron bars from grate above ground 1ft Material Required *Puddle swishContinue reading “multiple diesel fuel combustion chambers Incinerator”

HICLOVER Waste Incinerators

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste,Continue reading “HICLOVER Waste Incinerators”

Smaller animal cremators incinerator

Smaller cremators that will run diesel and will be capable of doing all the other dogs/cats/pets that we have. We only cremate pets individually so this is what we require. Have your company as member of Markis Hospital waste management group as planer or supplier, contractor of solutions or operating partners of the solution ofContinue reading “Smaller animal cremators incinerator”