Incinerator design for hospitals

Items/Model TS300(PLC) Picture Principle Solid Waste Incineration Treatment Burn Rate Average 300 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 170x120x100cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Average 38(DO) Gas Consumption (m3/hour) Average 45.6(NG) Temperature MonitorContinue reading “Incinerator design for hospitals”

Biomedical waste management ppt

Items/Model TS50(PLC) Picture Principle Medical Waste Incineration,dual chamber incinerator Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2 Temperature Monitor Digital Display Temperature ProtectionContinue reading “Biomedical waste management ppt”

Medical Waste Management System

Items/Model TS50(PLC) Picture Principle Medical Waste Incineration Burn Rate 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Gas Flue Washing System incineration of medical waste Feed Mode Manual Voltage 220V Power 4.0 Kw Oil Consumption (kg/hour) average 16.9 Gas Consumption (m3/hour) average 20.2Continue reading “Medical Waste Management System”

Incinerator for Waste Management Facility and Spare Parts

Items/Model TS500(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 500 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700Liters (2.7m3) Internal Dimensions 190x120x120cm Secondary Chamber 1300Liters (1.3m3) Smoke Filter Chamber Dry Scrubber Chamber Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (kg/hour) Average 44(DO) Gas Consumption (m3n/hour) Average 53(NG) Temperature Monitor DigitalContinue reading “Incinerator for Waste Management Facility and Spare Parts”

guidelines on waste management Incinerator Model YD-20C

Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Mobile Type Incinerator Phone: +86-13813931455(whatsapp/wechat) Website: http://www.hiclover.com/ Email: sales@hiclover.com Email: hicloversales@gmail.com Nanjing Clover MedicalContinue reading “guidelines on waste management Incinerator Model YD-20C”

MEDICAL WASTE INCINERATOR

Phone: +86-13813931455(whatsapp/wechat) Website: http://www.hiclover.com/ Email: sales@hiclover.com Email: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. 1. Incinerator 10kg per hr 2. Incinerator 20kg per hr 3. Incinerator 50kg per hr 4. Incinerator 100kg per hr 5. INDOOR INCINERATOR HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three CombustionContinue reading “MEDICAL WASTE INCINERATOR”

what are the main products of incineration process

Items/Model TS800 Picture Principle Animal Waste Incineration Treatment Burn Rate Average 300-450 kg/hour Feed Capacity Average 1200kg/feeding Control Mode Electric Control Combustion Chamber 3000Liter Internal Dimensions 300*100*100 cm Secondary Chamber *** Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) *** waste to energy plants cost Gas Consumption (m3/hour) Ave.22.8m3n/hr Temperature Monitor Digital DisplayContinue reading “what are the main products of incineration process”

Hazardous waste treatment and disposal

Items/Model TS50 Picture Principle Medical Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 100kg/feeding Control Mode Electric Controller Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke Filter Chamber Wet Scrubber System, 3 section type/ guidelines on waste management Feed Mode Manual Voltage 380V Power 10 Kw Oil Consumption (kg/hour) ***Continue reading “Hazardous waste treatment and disposal”

steps of waste management

Item Specification Model A1500 Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – yes Cow – small Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Wet Scrubber( Washing Tower) Incinerator Control Case Chimney:10.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 03Continue reading “steps of waste management”

what is medical waste management

Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Phone: +86-13813931455(whatsapp/wechat) Website: http://www.hiclover.com/ Email: sales@hiclover.com Email: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. bioContinue reading “what is medical waste management”